Global
Go to local country site
GEA Heat Exchangers / Global

GEA Heat Exchangers Ltd. - GEA Cooling Tower Solutions

Company Profile

Wet or Dry ... GEA Stands Out From the Crowd

GEA Power Cooling, Inc. incorporates leading technology and lifetime customer support in its wet and dry cooling solutions, providing superior performance and years of cost effective service with minimal maintenance requirements.

 

Extensive aftermarket replacement parts, repairs and services are provided for any existing system, no matter what brand. GEA aftermarket products and services optimize production, ensure continuous operation and extend service life at minimal cost.

Wet Cooling Solutions

  • Counterflow Cooling Towers
  • Crossflow Cooling Towers
  • Plume Abated Cooling Towers

Dry Cooling Solutions

  • Air-Cooled Condenser (ACC)
  • Parallel Condensing Systems
    • Case studies
    • Air Cooling

      Athens Power Station (2000) — plumeless ACC technology to meet clean air, low noise and aesthetic requirements. GEA’s first North American installation using ALEX heat exchanger technology.

      Dighton Power Project (1997) — first U.S. merchant power plant, built without a power purchase agreement so the Owner could sell power on the open (spot) market. Owner elected to use dry cooling technology in order to expedite the permitting process.

      El Dorado Energy (1998) — showcases modular construction ACC, the first of its kind, where fan modules could be built on the ground before being lifted and set on the structure by large cranes.

      Exeter Energy Project (1989) — this PAC SYSTEM operates at a steam turbine exhaust pressure of 2.9 in. HgA at an ambient air temperature of 89° F for higher power production while saving the owner more than half the cost of an all-dry system.

      Hunterstown (2001) — large combined cycle power station located in Pennsylvania (near Gettysburg) had very low noise requirements.

      Linden Cogeneration Project (1991) — largest dry-cooled power plant in North America at the time of installation, this plant utilizes three ACC systems arranged in a contiguous structure. This project was among the first of GEA’s "low noise" condensers, requiring the use of specially designed fans.

      Millmerran Power Project (1999) — 840 MW coal-fired plant located west of Brisbane in Queensland (Australia) required two ACC systems with modular construction features to maximize grade level assembly and installation productivity.

      Moapa Energy Facility (2001) — located 20 miles north of Las Vegas, Moapa is the largest power plant in the world that was built as a full "merchant" facility (without a PPA).

      Saranac Energy Plant (1994) — ACC comprised of 25 cells, designed to meet cold weather requirements.

      SEMASS Waste to Energy Facility (1999) — low-noise design required PAC SYSTEM technology. Retrofit project increased condensing capacity by approximately 20%.

      Streeter Generating Station (1994) — proximity to a highway where icing could occur meant converting this 20-year-old plant in Cedar Falls, Iowa, to GEA’s PAC SYSTEM by adding an ACC operating in parallel with the existing wet cooling system.

      Tucuman Power Station (1997) — Pluspetrol Energy of Argentina wanted to convert their existing simple cycle power plant to a 450 MW combined cycle plant, but their well water supply could only provide about 50% of the water required for an all wet heat rejection system. GEA’s PAC SYSTEM satisfied these constraints.

      Union County Resource Recovery Facility (2001) — ACC originally comprised of 9 cells, expanded to 12 cells. Complete overhaul of the plant’s Control Logic was part of this turnkey project.

      University of Alberta (2001) — cogeneration plant needed to generate electricity during the day and supply steam (for heating) during the night for the campus.

      Wyodak Station (1977) — 330 MW coal-fired plant, where ambient temperatures range from -48°F to 107°F and wind speeds can reach over 80 mph. GEA’s ACC systems have operated here successfully and reliably for more than 35 years without causing a single hour of forced outage.

       

    • Wet cooling

      Martin County Expansion — 22-cell fiberglass cooling tower designed to withstand hurricane force winds of south Florida.

      INEOS Phenol Expansion — Original 6-cell Douglas Fir structure tower was expanded with two additional fiberglass cells.

      Jasper County — NF-20 modular splash fill was provided to eliminate fouling problems. Along with the main, 11-cell fiberglass cooling tower, a 3-cell cooling tower was constructed for use with the turbine inlet air chilling system.

      Forney Power Project — This 22-cell wood cooling tower is the longest continuous structure ever built by GEA.

      Rhodia — Tear down and rebuild an existing 2-cell wood crossflow tower and replace with a 2-cell film filled counterflow tower with a fiberglass structure.

      Metro Area Total Energy Plant — Cooling tower built to service a new chiller unit for the Metro Area Total Energy Plant which provides heating and cooling to all hospitals in downtown Boston, Massachusetts area.

      PICO Power Project — Plume abated cooling tower with fiberglass structure was built with a dry cooling section designed to reduce the relative humidity of the exit air. This was necessary to prevent fogging conditions on nearby highways and the San Jose International Airport.

      AES Hawaii — Located on the island of Oahu, Hawaii, this 200 MW coal fired power plant provides 16% of power for the island. A fiberglass cooling tower was built in 1999 to replace a deteriorating wood tower.

      Plant Branch — This 32-cell tower with a water flow rate of 400,000 gpm was installed along the banks of Georgia's Lake Lanier. It is the largest mechanical draft cooling tower built by GEA.
       

    • Employment
    • GEA Power Cooling, Inc. is an equal opportunity employer. It is our policy to recruit, employ, develop, and promote qualified individuals without regard to race, color, religion, sex, national origin, ancestry, age, marital status, handicap, or veteran status. This policy relates to all phases of employment including (but not limited to) recruiting, employment, placement, upgrading, training, demotion, transfer, lay-off, recall, termination, rates of pay or other forms of compensation, and participation in all Company-sponsored activities.
       
      GEA Power Cooling, Inc. is a world leader in providing Cooling Systems for Power and Process industries using Wet, Dry, and Hybrid Technologies, with headquarters in Lakewood, Colorado. The company is part of a global technology group with a European parent and total annual sales of over $5 Billion.
       
      GEA Power Cooling, Inc. participates in E-Verify. We will provide the Social Security Administration (SSA) and , if necessary, the Department of Homeland Security (DHS), with information from each new employee’s  Form I-9 to confirm work authorization.
       

    • Services
    • The Aftermarket Services Division of GEA Power Cooling, Inc. provides an extensive range of replacement products and aftermarket services for any existing wet or dry cooling installation. Aftermarket Services, with headquarters in Clearwater, Florida, is a division of GEA Power Cooling, Inc., dedicated to supporting customers throughout North and South America.

      From inspection and preventive maintenance to upgrades, extension cells and replacement parts for any brand of cooling tower and air-cooled condenser, you can trust the Aftermarket Services Division of GEA to maximize performance and minimize costs. We take pride in the quality of our field engineering services for onsite operator training, start-up and commissioning assistance. We are well recognized for our responsive attention and dedication to our customers as well as our ability to optimize production and ensure continuous operation at maximum capacity.

      The Aftermarket Services Division provides:

      •Spare parts and service for all makes of existing cooling towers and air-cooled condensers

      •Inspection service

      •Repairs

      •Preventive maintenance

      •Replacement towers

      •Extension cells

      •Upgrades

      •ACC expansion

      •PAC SYSTEM retrofit

      •Inlet Pre-humidification system (IPS)

      •Windscreens

      •Conversion to Variable Frequency Drives (VFDs)

      •Fin-Tube Cleaning System

      •Control Logic upgrade

      •Online monitoring system

      GEA Power Cooling's Aftermarket Services Division ensures cost-effective, enhanced system performance and optimum plant output