TUBEdek® Lamella Clarifiers, also called tube settlers, are used for solids removal (sedimentation processes) in water and sewage treatment. TUBEdek® can be used in rectangular and in circular tanks.
Sludge, sand and silts in surface water, chemical precipitation and flocculation form solids which have to be removed. The most economic process to remove this pollution is parallel plate sedimentation.
TUBEdek® lamella clarifiers base on this physical principle. They consist of single profiles, which are assembled to a module forming several adjacent tubes and multiple sedimentation planes. This design increases the sedimentation area by a factor of 6 to 15 per square meter footprint. Using TUBEdek® tube settlers therefore decreases costs by being able to build smaller tanks.
Flexibility for all different applications
Our different tube settler types enable optimized sewage treatment processes. By choosing different tube lengths and heights and by varying the inclination angle, TUBEdek® settlers can be adjusted to all kinds of process requirements and tank geometry.
Engineering support
Please use our long experience and application know-how and ask for support in designing your clarifier or sedimentation tank.
TUBEdek® Typical Applications
FS 41.84 | FS 41.62 | FS 41.50 FS 42.50 | KLP 638
| |
Potable and process water | --- | Highly loaded surface water | Surface water Groundwater Filter backwash water | Low solids load polishing
|
Waste water | Primary sedi-mentation Activated sludge with low sludge volume | Stormwater Humus tanks behind fixed film processes | Aquaculture Humus tanks behind fixed film processes Flocculated water Stormwater | Aqua-culture Polishing |
Technical data
FS 41.84 | FS41.62 | FS 41.50 | FS 42.50 | KLP 638
| |
Material | PVC PPTV | PPTV | PVC PPTV | PPTV | PPTV
|
Sedimentation area / Slope 60° (m²/m³) | 6.25 | 8 | 11 | 12 | 15
|
Sedimentation area / Slope 55°(m²/m³) | 7 | 9 | 13 | 13.5 | -
|
Vertical module height (H/mm) | 700-2000 | On request | 500-2000 | 500-1000 | 610
|
Standard module height (H/mm) | 1000/ 1500 | 1000 | 1000 | 1000 | 610
|
Lamella pitch (mm) | 83 (+/-1) | 64 (+/-1) | 45 (+/-1) | 43 (+/-1) | 33 (average)
|
Hydraulic radius (cm) | 2.6 | 2.5 | 1.7 | 1.6 | 1.7
|
Contin. operation temp. Max operation temp. PVC (°C) | 55 60 (short term) | - | 55 60 (short term) | - | -
|
Contin. operation temp. Max operation temp. PPTV (°C) | 70 80 (short term) | 70 80 (short term) | 70 80 (short term) | 70 80 (short term) | 70 80 (short term) |