CMDR

Polacel CMDR Series

Counter-Flow Modular Cooling Tower

Print

The Polacel CMDR cooling tower concept can process large quanti­ties of water and it has a substan­tial cooling capacity. The modular CMDR systems are easy to adjust to cooling require­ments and the available space, whether they are used singly or in series. The cooling perfor­mance of these cooling towers is optimal and operation is problem free. With a 95%+ saving in water, the efficient CMDR systems are the best choice for man and his environ­ment.

  • Polacel CMDR Series Modular Cooling Tower
    Polacel CMDR Series
  • Polacel CMDR Series
    Polacel CMDR Series
  • Polacel CMDR Series
    Polacel CMDR Series
  • Polacel CMDR Series
    Polacel CMDR Series

Cooling needs: demand = supply

The cooling water tem­pera­tures (inlet and outlet), the wet bulb tem­pera­ture, noise and the water load are the four most important factors in the selection of a cooling tower. Polacel makes an inventory of the require­ments together with the client and uses this inventory as the basis of the design for a suitable solution.

There are standard solutions in the modular CMDR system for virtually any capacity require­ment. Polacel engineers make custo­mized changes to meet special require­ments.

Fast and flexible con­struc­tion

We can build these cooling towers in a very limited time frame thanks to the struc­tural quality and the flexible appli­cation options offered by the modular CMDR concept.

For example, the CMDR system can be assembled prior to a shutdown (along­side the existing operating cooling tower) and then be hoisted as a complete unit and installed on the existing water basin during the shutdown. This is why the construc­tion time of a Polacel cooling tower always fits into your schedule.

    • CMDR 135 - CMDR 380
    • Type
      CMDR 135
      CMDR 160
      CMDR 180
      CMDR 210
      CMDR 240
      CMDR 300
      CMDR 380
      Wet surface (m²)
      13
      16
      18
      21
      24
      30
      38
      Q min (m³/h)
      91
      112
      126
      147
      168
      210
      266
      Q max (m³/h)
      455
      560
      576
      735
      840
      1,050
      1,216
      Lenght (mm)
      3,720
      4,380
      4,980
      4,980
      4,980
      6,240
      6,240
      Width (mm)
      3,720
      3,720
      3,720
      4,380
      4,980
      4,980
      6,240
      Height (mm)
      4,890
      5,275
      5,325
      5,455
      5,925
      6,105
      6,235
      Weight empty (kg)
      2,870
      3,420
      3,420
      4,180
      4,850
      6,280
      8,060
      Weight operational (kg)
      6,320
      7,500
      7,500
      9,740
      11,260
      14,490
      22,650
      Drive type

      geared motor

      • All data is for information only. Please contact us for certified data.
      • All types are available with different air speeds and different fills.
      • We have extensive specifications for all cooling towers listed above.
    • CMDR 460 - CMDR 1200
    • Type
      CMDR 460
      CMDR 540
      CMDR 630
      CMDR 740
      CMDR 840
      CMDR 960
      CMDR 1200
      Wet surface (m²)
      46
      54
      63
      74
      84
      96
      120
      Q min (m³/h)
      322
      378
      441
      518
       
      Q max (m³/h)
      1,472
      1,728
      2,016
      2,368
      Lenght (mm)
      7,440
      7,440
      8,640
      7,440
      Width (mm)
      6,240
      7,440
      7,440
      7,440
      Height (mm)
      6,385
      6,785
      6,785
      6,785
      Weight empty (kg)
      9,650
      11,740
      13,310
      15,630
      Weight operational (kg)
      27,420
      33,100
      38,070
      44,700
      Drive type

      geared motor

      • All data is for information only. Please contact us for certified data.
      • All types are available with different air speeds and different fills.
      • We have extensive specifications for all cooling towers listed above.