XT

Polacel XT Series

Cross-Flow Modula Cooling Tower

Print

The Polacel cross flow cooling tower is quiet and economical, and has a high cooling capacity. The modular system can be easily adjusted to suit cooling require­ments and the space available. The cooling towers have optimal perfor­mance and run problem-free. The consi­derable savings in water usage (95%+), and the excep­tio­nally low noise level make the economical crossflow cooling towers the best choice for both man and the environ­ment.

  • Polacel XT Series Modular Cooling Tower
    Polacel XT Series
  • Polacel XT Series
    Polacel XT Series
  • Polacel XT Series
    Polacel XT Series
  • Polacel XT Series
    Polacel XT Series

Struc­tural qualities

The advanced design engi­neering has also resulted in a number of special struc­tural advan­tages:

  • Only a minimum number of support points are necessary as a result of the self-suppor­ting founda­tions and the high internal rigidity.
  • Where possible, fully portable and instal­led ready to go.
  • The Polacel frost-proof polyes­ter water pan can withstand sub-zero tem­pera­tures. Essential for free-cooling appli­cations.
  • Due to their low profile, cross flow cooling towers present fewer aesthe­tic problems.
  • The expan­dable modular system has virtu­ally no limita­tions in terms of shape and size.
  • All struc­tural design princi­ples are analysed and tested in advance using dynamic calcula­tions and compu­ter studies.

Durable and reliable

We design and manu­fac­ture cooling towers that have a long life and require a minimum of main­te­nance. This perfor­mance is achieved by a careful choice of materials - stainless steel combined with glass fibre rein­forced polyes­ter and plastics - the excep­tional­ly sound design and the conside­rable expe­rience of our engi­neers.

'Cheap and cheerful' solutions such as fans with a V-belt drive, or painted panels, are avoided. The result is a cooling tower that is low mainte­nance, econo­mical and able to deliver a consis­tently high quality, problem-free perfor­mance.

    • XT2.240 Models
    • Type
      XT2.240-135
      XT2.240-185
      XT2.240-235
      Wet surface (m²)
      2.88
      2.88
      2.88
      Q min (m³/h)
      23
      23
      23
      Q max (m³/h)
      160
      160
      160
      Lenght (mm)
      2,710
      2,710
      2,710
      Width (mm)
      3,480
      3,480
      3,480
      Height (mm)
      2,460
      2,960
      3,460
      Weight empty (kg)
      1,250
      1,415
      1,575
      Weight operational (kg)
      5,250
      5,520
      5,825
      Number of enignes
      1
      1
      1
      • All data is for information only. Please contact us for certified data.
      • All types are available with different air speeds and different fills.
      • We have extensive specifications for all cooling towers listed above.
    • XT2.480 Models
    • Type
      XT2.480-135
      XT2.480-185
      XT2.480-235
      Wet surface (m²)
      5,76
      5,76
      5,76
      Q min (m³/h)
      46
      46
      46
      Q max (m³/h)
      320
      320
      320
      Lenght (mm)
      5,320
      5,320
      5,320
      Width (mm)
      3,480
      3,480
      3,480
      Height (mm)
      2,460
      2,960
      3,460
      Weight empty (kg)
      2,425
      2,750
      3,050
      Weight operational (kg)
      10,425
      11,050
      11,50
      Number of enignes
      2
      2
      2
      • All data is for information only. Please contact us for certified data.
      • All types are available with different air speeds and different fills.
      • We have extensive specifications for all cooling towers listed above.
    • XT2.720 Models
    • Type
      XT2.720-135
      XT2.720-185
      XT2.720-235
      Wet surface (m²)
      8,64
      8,64
      8,64
      Q min (m³/h)
      69
      69
      69
      Q max (m³/h)
      480
      480
      480
      Lenght (mm)
      7,750
      7,750
      7,750
      Width (mm)
      3,480
      3,480
      3,480
      Height (mm)
      2,460
      2,960
      3,460
      Weight empty (kg)
      3,675
      4,200
      4,625
      Weight operational (kg)
      15,675
      16,575
      17,400
      Number of enignes
      3
      3
      3
      • All data is for information only. Please contact us for certified data.
      • All types are available with different air speeds and different fills.
      • We have extensive specifications for all cooling towers listed above.
Top